{"product_id":"schneider-electric-lc1d18-contactor","title":"Schneider Electric LC1D18 Contactor","description":"\u003ch2 data-end=\"455\" data-start=\"390\"\u003e\u003cstrong data-end=\"455\" data-start=\"396\"\u003eSchneider Electric LC1D18 Contactor – TeSys Deca Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-end=\"473\" data-start=\"457\"\u003e\u003cstrong data-end=\"473\" data-start=\"461\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"896\" data-start=\"474\"\u003eThe \u003cstrong data-end=\"507\" data-start=\"478\"\u003eSchneider Electric LC1D18\u003c\/strong\u003e is a powerful \u003cstrong data-end=\"542\" data-start=\"522\"\u003e3-pole contactor\u003c\/strong\u003e from the \u003cstrong data-end=\"573\" data-start=\"552\"\u003eTeSys Deca Series\u003c\/strong\u003e (formerly TeSys D), designed for \u003cstrong data-end=\"635\" data-start=\"607\"\u003eindustrial motor control\u003c\/strong\u003e and high-demand power applications.\u003cbr data-end=\"674\" data-start=\"671\"\u003eWith a \u003cstrong data-end=\"714\" data-start=\"681\"\u003ecurrent rating of 18 A (AC-3)\u003c\/strong\u003e and a \u003cstrong data-end=\"767\" data-start=\"721\"\u003epower rating up to 7.5 kW \/ 10 HP at 400 V\u003c\/strong\u003e, the LC1D18 provides robust, reliable control for \u003cstrong data-end=\"837\" data-start=\"818\"\u003eelectric motors\u003c\/strong\u003e, \u003cstrong data-end=\"848\" data-start=\"839\"\u003epumps\u003c\/strong\u003e, \u003cstrong data-end=\"865\" data-start=\"850\"\u003ecompressors\u003c\/strong\u003e, and \u003cstrong data-end=\"893\" data-start=\"871\"\u003eautomation systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-end=\"1167\" data-start=\"898\"\u003eBuilt to meet international standards, including \u003cstrong data-end=\"959\" data-start=\"946\"\u003eIEC 60947\u003c\/strong\u003e, \u003cstrong data-end=\"973\" data-start=\"961\"\u003eUL 60947\u003c\/strong\u003e, and \u003cstrong data-end=\"992\" data-start=\"979\"\u003eCSA C22.2\u003c\/strong\u003e, the LC1D18 delivers superior performance in demanding three-phase power environments while maintaining the same compact, \u003cstrong data-end=\"1134\" data-start=\"1115\"\u003eDIN-rail design\u003c\/strong\u003e as the LC1D09 and LC1D12 models.\u003c\/p\u003e\n\u003chr data-end=\"1172\" data-start=\"1169\"\u003e\n\u003ch3 data-end=\"1197\" data-start=\"1174\"\u003e🔑 \u003cstrong data-end=\"1197\" data-start=\"1181\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"1801\" data-start=\"1198\"\u003e\n\u003cli data-end=\"1232\" data-start=\"1198\"\u003e\n\u003cp data-end=\"1232\" data-start=\"1200\"\u003e\u003cstrong data-end=\"1225\" data-start=\"1200\"\u003eRated Current (AC-3):\u003c\/strong\u003e 18 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1292\" data-start=\"1233\"\u003e\n\u003cp data-end=\"1292\" data-start=\"1235\"\u003e\u003cstrong data-end=\"1252\" data-start=\"1235\"\u003ePower Rating:\u003c\/strong\u003e up to 7.5 kW (10 HP at 400 V 3-phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1385\" data-start=\"1293\"\u003e\n\u003cp data-end=\"1385\" data-start=\"1295\"\u003e\u003cstrong data-end=\"1330\" data-start=\"1295\"\u003eOperating Coil Voltage \u003cem\u003eOptions\u003c\/em\u003e:\u003c\/strong\u003e 24 V, 48 V, 110 V, 230 V (AC or DC voltage versions)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1522\" data-start=\"1432\"\u003e\n\u003cp data-end=\"1522\" data-start=\"1434\"\u003e\u003cstrong data-end=\"1448\" data-start=\"1434\"\u003eCoil Type:\u003c\/strong\u003e Low-inrush \u003cstrong data-end=\"1496\" data-start=\"1460\"\u003eelectromagnetic power relay coil\u003c\/strong\u003e for efficient switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1582\" data-start=\"1523\"\u003e\n\u003cp data-end=\"1582\" data-start=\"1525\"\u003e\u003cstrong data-end=\"1542\" data-start=\"1525\"\u003eContact Type:\u003c\/strong\u003e 3 main poles + 1 auxiliary (NO or NC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1634\" data-start=\"1583\"\u003e\n\u003cp data-end=\"1634\" data-start=\"1585\"\u003e\u003cstrong data-end=\"1598\" data-start=\"1585\"\u003eMounting:\u003c\/strong\u003e Quick \u003cstrong data-end=\"1632\" data-start=\"1605\"\u003eDIN rail or screw mount\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1698\" data-start=\"1635\"\u003e\n\u003cp data-end=\"1698\" data-start=\"1637\"\u003e\u003cstrong data-end=\"1651\" data-start=\"1637\"\u003eTerminals:\u003c\/strong\u003e Rugged \u003cstrong data-end=\"1678\" data-start=\"1659\"\u003escrew terminals\u003c\/strong\u003e for secure wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1776\" data-start=\"1699\"\u003e\n\u003cp data-end=\"1776\" data-start=\"1701\"\u003e\u003cstrong data-end=\"1715\" data-start=\"1701\"\u003eStandards:\u003c\/strong\u003e \u003cstrong data-end=\"1728\" data-start=\"1716\"\u003eUL 60947\u003c\/strong\u003e, \u003cstrong data-end=\"1743\" data-start=\"1730\"\u003eIEC 60947\u003c\/strong\u003e, \u003cstrong data-end=\"1758\" data-start=\"1745\"\u003eCSA C22.2\u003c\/strong\u003e, RoHS Compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1801\" data-start=\"1777\"\u003e\n\u003cp data-end=\"1801\" data-start=\"1779\"\u003e\u003cstrong data-end=\"1790\" data-start=\"1779\"\u003eUNSPSC:\u003c\/strong\u003e 39121529\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1806\" data-start=\"1803\"\u003e\n\u003ch3 data-end=\"1830\" data-start=\"1808\"\u003e⚡ \u003cstrong data-end=\"1830\" data-start=\"1814\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"1880\" data-start=\"1831\"\u003eThe \u003cstrong data-end=\"1866\" data-start=\"1835\"\u003eLC1D18 TeSys Deca contactor\u003c\/strong\u003e is ideal for:\u003c\/p\u003e\n\u003cul data-end=\"2163\" data-start=\"1881\"\u003e\n\u003cli data-end=\"1939\" data-start=\"1881\"\u003e\n\u003cp data-end=\"1939\" data-start=\"1883\"\u003e\u003cstrong data-end=\"1914\" data-start=\"1883\"\u003eThree-phase electric motors\u003c\/strong\u003e (up to 7.5 kW \/ 10 HP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2060\" data-start=\"2003\"\u003e\n\u003cp data-end=\"2060\" data-start=\"2005\"\u003e\u003cstrong data-end=\"2035\" data-start=\"2005\"\u003ePower distribution systems\u003c\/strong\u003e and \u003cstrong data-end=\"2058\" data-start=\"2040\"\u003econtrol panels\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2100\" data-start=\"2061\"\u003e\n\u003cp data-end=\"2100\" data-start=\"2063\"\u003e\u003cstrong data-end=\"2098\" data-start=\"2063\"\u003ePumps, fans, compressors, and HVAC equipment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2163\" data-start=\"2101\"\u003e\n\u003cp data-end=\"2163\" data-start=\"2103\"\u003e\u003cstrong data-end=\"2161\" data-start=\"2103\"\u003eWater treatment plants and industrial automation racks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2311\" data-start=\"2165\"\u003eIt’s designed for continuous-duty performance with a \u003cstrong data-end=\"2238\" data-start=\"2218\"\u003ehigh AC-3 rating\u003c\/strong\u003e, excellent \u003cstrong data-end=\"2276\" data-start=\"2250\"\u003ecoil voltage stability\u003c\/strong\u003e, and extended \u003cstrong data-end=\"2310\" data-start=\"2291\"\u003emechanical life\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-end=\"2316\" data-start=\"2313\"\u003e\n\u003ch3 data-end=\"2350\" data-start=\"2318\"\u003e🧱 \u003cstrong data-end=\"2350\" data-start=\"2325\"\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-end=\"2682\" data-start=\"2351\"\u003eThe LC1D18 shares the modular architecture of the \u003cstrong data-end=\"2422\" data-start=\"2401\"\u003eTeSys Deca Series\u003c\/strong\u003e, ensuring seamless integration with overload relays, auxiliary blocks, and surge suppressors.\u003cbr data-end=\"2519\" data-start=\"2516\"\u003eIts \u003cstrong data-end=\"2541\" data-start=\"2523\"\u003eoperating coil\u003c\/strong\u003e minimizes \u003cstrong data-end=\"2574\" data-start=\"2552\"\u003einrush consumption\u003c\/strong\u003e, extending both \u003cstrong data-end=\"2634\" data-start=\"2591\"\u003eelectrical life (\u0026gt;1 million operations)\u003c\/strong\u003e and \u003cstrong data-end=\"2679\" data-start=\"2639\"\u003emechanical life (\u0026gt;10 million cycles)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul data-end=\"2840\" data-start=\"2684\"\u003e\n\u003cli data-end=\"2725\" data-start=\"2684\"\u003e\n\u003cp data-end=\"2725\" data-start=\"2686\"\u003e\u003cstrong data-end=\"2702\" data-start=\"2686\"\u003ePole Number:\u003c\/strong\u003e 3 main + 1 auxiliary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2794\" data-start=\"2726\"\u003e\n\u003cp data-end=\"2794\" data-start=\"2728\"\u003e\u003cstrong data-end=\"2743\" data-start=\"2728\"\u003eDimensions:\u003c\/strong\u003e HANDLE SIZE 3\/4\" × 2-5\/8\", OVERALL LENGTH 5-7\/8\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2840\" data-start=\"2795\"\u003e\n\u003cp data-end=\"2840\" data-start=\"2797\"\u003e\u003cstrong data-end=\"2812\" data-start=\"2797\"\u003ePOINT SIZE:\u003c\/strong\u003e 7 for easy identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2845\" data-start=\"2842\"\u003e\n\u003ch3 data-end=\"2880\" data-start=\"2847\"\u003e🧩 \u003cstrong data-end=\"2880\" data-start=\"2854\"\u003eCompatible Accessories\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-end=\"3188\" data-start=\"2881\"\u003e\n\u003cli data-end=\"2934\" data-start=\"2881\"\u003e\n\u003cp data-end=\"2934\" data-start=\"2883\"\u003e\u003cstrong data-end=\"2912\" data-start=\"2883\"\u003eSquare D Overload Relays:\u003c\/strong\u003e LRD16, LRD21, LRD32\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3007\" data-start=\"2935\"\u003e\n\u003cp data-end=\"3007\" data-start=\"2937\"\u003e\u003cstrong data-end=\"2960\" data-start=\"2937\"\u003eAuxiliary Contacts:\u003c\/strong\u003e LADN11, LADN22 (Square D Auxiliary Contacts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3068\" data-start=\"3008\"\u003e\n\u003cp data-end=\"3068\" data-start=\"3010\"\u003e\u003cstrong data-end=\"3050\" data-start=\"3010\"\u003eTransient Voltage Surge Suppressors:\u003c\/strong\u003e LA4DA1U, LA4DFU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3115\" data-start=\"3069\"\u003e\n\u003cp data-end=\"3115\" data-start=\"3071\"\u003e\u003cstrong data-end=\"3096\" data-start=\"3071\"\u003eGV2 Motor Protectors:\u003c\/strong\u003e GV2ME16, GV2ME20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3188\" data-start=\"3116\"\u003e\n\u003cp data-end=\"3188\" data-start=\"3118\"\u003e\u003cstrong data-end=\"3147\" data-start=\"3118\"\u003eReversing Contactor Kits:\u003c\/strong\u003e LC1D18 pairs with LAD9R1V kit (mechanical interlock and 2 bus bars)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"G7 (110\/120V AC)","offer_id":46958944846052,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"F7 (110V AC)","offer_id":46960134488292,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"LE7 (208V AC)","offer_id":46960134521060,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"M7 (220V AC)","offer_id":46960134553828,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"B7 (24V AC)","offer_id":46960134586596,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"BD 24V DC)","offer_id":46960134619364,"sku":null,"price":120.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0760\/1979\/4148\/files\/LC1D18.webp?v=1762378889","url":"https:\/\/motorcontrolsdirect.com\/products\/schneider-electric-lc1d18-contactor","provider":"Motor Controls Direct ","version":"1.0","type":"link"}