{"product_id":"schneider-electric-lc1d12-contactor","title":"Schneider Electric LC1D12 Contactor","description":"\u003ch2 data-start=\"301\" data-end=\"366\"\u003e\u003cstrong data-start=\"307\" data-end=\"366\"\u003eSchneider Electric LC1D12 Contactor – TeSys Deca Series\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"368\" data-end=\"384\"\u003e\u003cstrong data-start=\"372\" data-end=\"384\"\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"385\" data-end=\"672\"\u003eThe \u003cstrong data-start=\"389\" data-end=\"418\"\u003eSchneider Electric LC1D12\u003c\/strong\u003e is a rugged, high-performance \u003cstrong data-start=\"449\" data-end=\"469\"\u003e3-pole contactor\u003c\/strong\u003e from the \u003cstrong data-start=\"479\" data-end=\"500\"\u003eTeSys Deca Series\u003c\/strong\u003e(formerly TeSys D). Rated for \u003cstrong data-start=\"531\" data-end=\"547\"\u003e12 Amps AC-3\u003c\/strong\u003e, it provides dependable \u003cstrong data-start=\"572\" data-end=\"589\"\u003emotor control\u003c\/strong\u003e for \u003cstrong data-start=\"594\" data-end=\"623\"\u003ethree-phase power systems\u003c\/strong\u003e, pumps, HVAC units, and industrial automation.\u003c\/p\u003e\n\u003cp data-start=\"674\" data-end=\"921\"\u003eFully compliant with \u003cstrong data-start=\"695\" data-end=\"708\"\u003eIEC 60947\u003c\/strong\u003e, \u003cstrong data-start=\"710\" data-end=\"722\"\u003eUL 60947\u003c\/strong\u003e, and \u003cstrong data-start=\"728\" data-end=\"741\"\u003eCSA C22.2\u003c\/strong\u003e, the LC1D12 offers the same \u003cstrong data-start=\"770\" data-end=\"797\"\u003ecompact DIN-rail design\u003c\/strong\u003eand modular flexibility as the smaller LC1D09, but with a higher \u003cstrong data-start=\"863\" data-end=\"881\"\u003ecurrent rating\u003c\/strong\u003e for motors up to \u003cstrong data-start=\"899\" data-end=\"918\"\u003e5.5 kW (7.5 HP)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"923\" data-end=\"926\"\u003e\n\u003ch3 data-start=\"928\" data-end=\"951\"\u003e🔑 \u003cstrong data-start=\"935\" data-end=\"951\"\u003eKey Features\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"952\" data-end=\"1535\"\u003e\n\u003cli data-start=\"952\" data-end=\"986\"\u003e\n\u003cp data-start=\"954\" data-end=\"986\"\u003e\u003cstrong data-start=\"954\" data-end=\"979\"\u003eRated Current (AC-3):\u003c\/strong\u003e 12 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"987\" data-end=\"1049\"\u003e\n\u003cp data-start=\"989\" data-end=\"1049\"\u003e\u003cstrong data-start=\"989\" data-end=\"1006\"\u003ePower Rating:\u003c\/strong\u003e Up to 5.5 kW \/ 7.5 HP at 400 V (3-phase)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1050\" data-end=\"1141\"\u003e\n\u003cp data-start=\"1052\" data-end=\"1141\"\u003e\u003cstrong data-start=\"1052\" data-end=\"1087\"\u003eOperating Coil Voltage Options:\u003c\/strong\u003e 24 V, 48 V, 110 V, 230 V (AC \u0026amp; DC voltage versions)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1142\" data-end=\"1187\"\u003e\n\u003cp data-start=\"1144\" data-end=\"1187\"\u003e\u003cstrong data-start=\"1144\" data-end=\"1176\"\u003eOperating Voltage (Nominal):\u003c\/strong\u003e 220 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1285\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1285\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1204\"\u003eCoil Type:\u003c\/strong\u003e Low-inrush \u003cstrong data-start=\"1216\" data-end=\"1252\"\u003eelectromagnetic power relay coil\u003c\/strong\u003e for quiet, efficient operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1286\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1288\" data-end=\"1345\"\u003e\u003cstrong data-start=\"1288\" data-end=\"1305\"\u003eContact Type:\u003c\/strong\u003e 3 main poles + 1 auxiliary (NO or NC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1397\"\u003e\n\u003cp data-start=\"1348\" data-end=\"1397\"\u003e\u003cstrong data-start=\"1348\" data-end=\"1361\"\u003eMounting:\u003c\/strong\u003e Quick \u003cstrong data-start=\"1368\" data-end=\"1395\"\u003eDIN-rail or screw mount\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1398\" data-end=\"1447\"\u003e\n\u003cp data-start=\"1400\" data-end=\"1447\"\u003e\u003cstrong data-start=\"1400\" data-end=\"1414\"\u003eTerminals:\u003c\/strong\u003e Heavy-duty \u003cstrong data-start=\"1426\" data-end=\"1445\"\u003escrew terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1448\" data-end=\"1510\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1510\"\u003e\u003cstrong data-start=\"1450\" data-end=\"1465\"\u003eCompliance:\u003c\/strong\u003e \u003cstrong data-start=\"1466\" data-end=\"1478\"\u003eUL 60947\u003c\/strong\u003e, \u003cstrong data-start=\"1480\" data-end=\"1493\"\u003eIEC 60947\u003c\/strong\u003e, \u003cstrong data-start=\"1495\" data-end=\"1508\"\u003eCSA C22.2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1511\" data-end=\"1535\"\u003e\n\u003cp data-start=\"1513\" data-end=\"1535\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1524\"\u003eUNSPSC:\u003c\/strong\u003e 39121529\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1537\" data-end=\"1540\"\u003e\n\u003ch3 data-start=\"1542\" data-end=\"1564\"\u003e⚡ \u003cstrong data-start=\"1548\" data-end=\"1564\"\u003eApplications\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"1565\" data-end=\"1593\"\u003eThe \u003cstrong data-start=\"1569\" data-end=\"1579\"\u003eLC1D12\u003c\/strong\u003e is ideal for:\u003c\/p\u003e\n\u003cul data-start=\"1594\" data-end=\"1840\"\u003e\n\u003cli data-start=\"1594\" data-end=\"1639\"\u003e\n\u003cp data-start=\"1596\" data-end=\"1639\"\u003e\u003cstrong data-start=\"1596\" data-end=\"1615\"\u003eElectric motors\u003c\/strong\u003e up to 5.5 kW (7.5 HP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1640\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1642\" data-end=\"1696\"\u003e\u003cstrong data-start=\"1642\" data-end=\"1666\"\u003eReversing contactors\u003c\/strong\u003e and \u003cstrong data-start=\"1671\" data-end=\"1694\"\u003estar-delta starters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1697\" data-end=\"1754\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1754\"\u003e\u003cstrong data-start=\"1699\" data-end=\"1717\"\u003eControl panels\u003c\/strong\u003e and \u003cstrong data-start=\"1722\" data-end=\"1752\"\u003epower distribution systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1755\" data-end=\"1840\"\u003e\n\u003cp data-start=\"1757\" data-end=\"1840\"\u003e\u003cstrong data-start=\"1757\" data-end=\"1783\"\u003eWater treatment plants\u003c\/strong\u003e, \u003cstrong data-start=\"1785\" data-end=\"1803\"\u003eHVAC equipment\u003c\/strong\u003e, and \u003cstrong data-start=\"1809\" data-end=\"1840\"\u003eindustrial automation racks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1842\" data-end=\"1981\"\u003eIts robust \u003cstrong data-start=\"1853\" data-end=\"1868\"\u003eAC-3 rating\u003c\/strong\u003e and superior \u003cstrong data-start=\"1882\" data-end=\"1908\"\u003ecoil voltage stability\u003c\/strong\u003e make it perfect for continuous-duty service in demanding environments.\u003c\/p\u003e\n\u003chr data-start=\"1983\" data-end=\"1986\"\u003e\n\u003ch3 data-start=\"1988\" data-end=\"2020\"\u003e🧱 \u003cstrong data-start=\"1995\" data-end=\"2020\"\u003eConstruction \u0026amp; Design\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"2021\" data-end=\"2332\"\u003eLike all \u003cstrong data-start=\"2030\" data-end=\"2051\"\u003eTeSys Deca Series\u003c\/strong\u003e devices, the LC1D12 features a \u003cstrong data-start=\"2083\" data-end=\"2110\"\u003ecompact DIN-rail design\u003c\/strong\u003e that accepts the same accessories as the LC1D09 and LC1D18.\u003cbr data-start=\"2170\" data-end=\"2173\"\u003eThe \u003cstrong data-start=\"2177\" data-end=\"2191\"\u003erelay coil\u003c\/strong\u003e minimizes \u003cstrong data-start=\"2202\" data-end=\"2224\"\u003einrush consumption\u003c\/strong\u003e, extending both \u003cstrong data-start=\"2241\" data-end=\"2260\"\u003eelectrical life\u003c\/strong\u003e (\u0026gt;1 million operations) and \u003cstrong data-start=\"2289\" data-end=\"2308\"\u003emechanical life\u003c\/strong\u003e (\u0026gt;10 million cycles).\u003c\/p\u003e\n\u003cul data-start=\"2334\" data-end=\"2488\"\u003e\n\u003cli data-start=\"2334\" data-end=\"2373\"\u003e\n\u003cp data-start=\"2336\" data-end=\"2373\"\u003e\u003cstrong data-start=\"2336\" data-end=\"2352\"\u003ePole Number:\u003c\/strong\u003e 3 main + auxiliary\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2374\" data-end=\"2442\"\u003e\n\u003cp data-start=\"2376\" data-end=\"2442\"\u003e\u003cstrong data-start=\"2376\" data-end=\"2391\"\u003eDimensions:\u003c\/strong\u003e HANDLE SIZE 3\/4\" × 2-5\/8\", OVERALL LENGTH 5-7\/8\"\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2443\" data-end=\"2488\"\u003e\n\u003cp data-start=\"2445\" data-end=\"2488\"\u003e\u003cstrong data-start=\"2445\" data-end=\"2460\"\u003ePOINT SIZE:\u003c\/strong\u003e 7 for easy identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2490\" data-end=\"2493\"\u003e\n\u003ch3 data-start=\"2495\" data-end=\"2528\"\u003e🧩 \u003cstrong data-start=\"2502\" data-end=\"2528\"\u003eCompatible Accessories\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul data-start=\"2529\" data-end=\"2842\"\u003e\n\u003cli data-start=\"2529\" data-end=\"2582\"\u003e\n\u003cp data-start=\"2531\" data-end=\"2582\"\u003e\u003cstrong data-start=\"2531\" data-end=\"2560\"\u003eSquare D Overload Relays:\u003c\/strong\u003e LRD12, LRD16, LRD21\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2583\" data-end=\"2655\"\u003e\n\u003cp data-start=\"2585\" data-end=\"2655\"\u003e\u003cstrong data-start=\"2585\" data-end=\"2608\"\u003eAuxiliary Contacts:\u003c\/strong\u003e LADN11, LADN22 (Square D Auxiliary Contacts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2656\" data-end=\"2716\"\u003e\n\u003cp data-start=\"2658\" data-end=\"2716\"\u003e\u003cstrong data-start=\"2658\" data-end=\"2698\"\u003eTransient Voltage Surge Suppressors:\u003c\/strong\u003e LA4DA1U, LA4DFU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2717\" data-end=\"2778\"\u003e\n\u003cp data-start=\"2719\" data-end=\"2778\"\u003e\u003cstrong data-start=\"2719\" data-end=\"2743\"\u003eGV2 Motor Protectors\u003c\/strong\u003e and \u003cstrong data-start=\"2748\" data-end=\"2776\"\u003eReversing Contactor Kits\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2779\" data-end=\"2842\"\u003e\n\u003cp data-start=\"2781\" data-end=\"2842\"\u003e\u003cstrong data-start=\"2781\" data-end=\"2809\"\u003eAuxiliary Contact Blocks\u003c\/strong\u003e for additional NO\/NC functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"My Store","offers":[{"title":"BD (24VDC)","offer_id":46958389854436,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"B7 (24 VDC)","offer_id":46958389887204,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"F7 (110 VAC)","offer_id":46958389919972,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"G7 (110\/120 VAC)","offer_id":46958389952740,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"LE7 (208 VAC)","offer_id":46958389985508,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"M7 (220V)","offer_id":46958390018276,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"P7 (230 VAC)","offer_id":46958390051044,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"U7 (240 VAC)","offer_id":46958390083812,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false},{"title":"T7 480 VAC)","offer_id":46958390116580,"sku":null,"price":100.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0760\/1979\/4148\/files\/LC1D12.webp?v=1762377644","url":"https:\/\/motorcontrolsdirect.com\/products\/schneider-electric-lc1d12-contactor","provider":"Motor Controls Direct ","version":"1.0","type":"link"}